Wet areas (MMA)

Silikal system B (MMA)

In­dus­tri­al floors in wet use occur pre­dom­i­nant­ly in pro­duc­tion fa­cil­i­ties for the food in­dus­try. The choice of Si­likal sys­tem to use varies ac­cord­ing to the con­di­tions, e. g. slip re­sis­tance and re­sis­tance to the rel­e­vant media such as water, grease and clean­ing agents. The rec­om­mend­ed total thick­ness of the coat­ing is ap­prox. 4 – 6 mm.

SubstratePrimingMain Coat
Concrete
cement screed
Ceramic tiles
Silikal R 51
(concrete, cement screed)

Si­li­kal RU 727 + adhesion promotor Ad­di­tiv M (tiles)
Si­likal R 61/SL ap­prox. 3 mm
Si­likal R 61/SL ap­prox. 5 mm
DecorationsAdditional ItemColour Concept
Pig­ment­ed non-slip
Coloured quartz non-slip
Cov­ing with Si­likal HK 20
Scratch slur­ry with Si­likal RV 368